Qualys Knowledge Base Integration is failing

  • Rversion finale: Australia
  • Mis à jour 12 mars 2026
  • 1 minute de lecture
  • Resolve Qualys Knowledge Base Integration failure by reducing the payload attachment size received from Qualys to the specified limit.

    Avant de commencer

    Role required: sn_vul.vulnerability_admin

    Procédure

    1. Ensure that the payload attachment size is within the specified limit.
      1. Navigate to All > Qualys Vulnerability Integration > Integration Instances.
      2. Select the Integration Instance Parameters tab.
      3. Select max_delta_days and modify the default value to 3.
    2. If the integration still fails, perform the following steps:
      1. Navigate to All > Qualys Vulnerability Integration > Primary Integrations.
      2. Select Qualys Knowledge Base.
      3. Select the Integration Details tab.
      4. In the Start time field, select the current date to skip the execution of the run for that day.
      5. Navigate to All > Qualys Vulnerability Integration > Integration Instances.
      6. Select the Integration Instance Parameters tab.
      7. Select kb_backfill_full_import and modify the default value to true.

    Résultats

    Running the Qualys Knowledge Base Backfill integration updates all the third-party entries (TPEs) in the system. While the Qualys Host Detection integration creates a placeholder entry, the Qualys Knowledge Base Backfill integration updates it.