Data collector properties in Performance Analytics let you configure limits that protect and optimize the data collection process. These settings control script execution time, query duration, record counts, breakdown element limits, and error thresholds. The default values suit most environments, but adjustments should be made cautiously as increasing limits can affect system performance. Consulting a domain expert or implementation partner is recommended before changes.
Show less
Key Properties and Their Practical Use
- Script Timeout (com.snc.pa.dc.scripttimeout): Sets the max seconds a script runs per record during data collection. If exceeded, the record is skipped. Simplify scripts before increasing this from the default 30 seconds.
- Query Time Limit (com.snc.pa.dc.querytimelimit): Defines max minutes for a single query before logging a warning. Default is 60 minutes.
- Max Row Count for Indicator Sources:
- Non-optimized (com.snc.pa.dc.maxrowcountindicatorsource): Limits records collected per indicator source (default 50,000). Applies only if optimized collection is disabled.
- Optimized (com.snc.pa.dc.hsql.maxrowcountindicatorsource): Applies when optimized collection is enabled (default 1,000,000 records). Overrides non-optimized setting on upgrades beyond San Diego.
Warning: If record count exceeds these limits, no indicators are collected from that source. Overrides are possible per indicator source.
- Breakdown Elements Limits:
- Non-optimized (com.snc.pa.dc.maxbreakdownelementslimit): Max breakdown elements per source, default 10,000. Exceeding disables score collection from that source.
- Optimized (com.snc.pa.dc.hsql.maxbreakdownelementslimit): Default is unlimited (-1). Customers facing performance issues with large breakdown sources can set limits with support guidance.
- Breakdown Matrix Limits:
- Non-optimized (com.snc.pa.dc.maxbreakdownelementslevel2limit): Limits elements in two-level breakdown matrices (default 1,000,000). Exceeding prevents collection.
- Optimized (com.snc.pa.dc.hsql.maxbreakdownelementslevel2limit): Default unlimited (-1). Limits can be set with support consultation.
Note: Nested collection affects how element counts are computed for non-optimized collections.
- Max Error Count (com.snc.pa.dc.maxerrorcount): Stops data collection if errors exceed 500 in a job run. Errors typically stem from invalid scripts or timeouts. Review scripts if this limit is hit.
- Max Records in Snapshot (com.snc.pa.dc.maxrecords): Limits number of sys IDs stored in a Snapshot record to 5,000 by default. Exceeding this creates a partial list. Increasing this may degrade performance during data collection or Snapshot operations.
Practical Implications for ServiceNow Customers
These properties help balance thorough data collection with system performance and stability. Understanding and tuning them enables you to:
- Prevent long-running scripts and queries from impacting system responsiveness.
- Control data volumes collected from indicator and breakdown sources to avoid overload.
- Manage error thresholds to maintain data collection integrity.
- Monitor and limit the size of collected data snapshots to optimize storage and processing.
Because increasing limits can have significant performance impacts, it is best practice to keep default settings where possible and consult experts when adjustments are needed. Optimized data collection settings provide higher default limits and improved performance, making them suitable for larger data environments.
Data collector properties enable you to configure various limits for Performance Analytics data collection. The properties are configured to safeguard the data collection process. The default values are appropriate for most environments.
| Property | Description |
|---|---|
| com.snc.pa.dc.script_timeout | The maximum time in seconds that a script is allowed to run during a data collection cycle, such as an indicator source script or a breakdown script. This limit applies individually for each record processed by the data collection job. If a script exceeds this limit, the data collection job skips the current record. If your scripts frequently reach the default limit, simplify the scripts as much as possible before modifying this property.
|
| com.snc.pa.dc.query_time_limit | The maximum duration in minutes that a single query for a data collection job can run before a warning is logged.
|
| com.snc.pa.dc.max_row_count_indicator_source | The maximum number of records that a job can collect from a single indicator source. Important:
This property applies
only to jobs that do not use optimized data collection. If optimized data collection is enabled, which is the default condition, see the property
com.snc.pa.dc.hsql.max_row_count_indicator_source. This limit applies separately to each indicator source included in a data collection job. The number of indicators associated with each indicator source does not affect this limit. For example, if a data collection job collects scores for 12 indicators from three indicator sources, the job can collect a maximum of 150,000 records by default: 50,000 from each indicator source. Warning:
|
| com.snc.pa.dc.hsql.max_row_count_indicator_source | The maximum number of records that a job can collect from a single indicator source. Important:
This property applies only to jobs that use optimized data collection. Otherwise, com.snc.pa.dc.max_row_count_indicator_source applies. For more information, see Optimizing data collection. This limit applies separately to each indicator source included in a data collection job. The number of indicators associated with each indicator source does not affect this limit. For example, if a data collection job collects scores for 12 indicators from three indicator sources, the job can collect a maximum of 3 million records by default: 1 million from each indicator source. On upgrade to a later version than San Diego, the optimized data collector becomes enabled. This property then overrides com.snc.pa.dc.max_row_count_indicator_source. The value of the new property is set to the default 1 million, unless the value of com.snc.pa.dc.max_row_count_indicator_source was more than 1 million. In the latter case, the original property value is retained. Warning:
|
| com.snc.pa.dc.max_breakdown_elements_limit | Maximum number of breakdown elements retrieved by data collection for each breakdown source. If the number of elements on a breakdown source exceeds this limit, the data collector does not collect scores from that breakdown source. Important: This property applies only to jobs that do not use optimized data collection. For optimized data collection, see the property com.snc.pa.dc.hsql.max_breakdown_elements_limit. Also
see Optimizing data collection. This limit applies separately to each breakdown source included in a data collection job. The number of breakdowns associated with each breakdown source does not affect this limit. For example, if a data collection job collects scores for 12 breakdowns from three breakdown sources, the job can collect a maximum of 30,000 records by default: 10,000 from each breakdown source.
Warning: Increasing this limit increases the processing load on the node. This property is handled differently depending on whether nested collection is enabled: If nested collection is enabled, only elements with non-null scores count against this limit. The count is taken as the data collection job runs. When the number of elements with scores reaches this limit, the breakdown source is disabled and the scores cleared from memory. When nested collection is not enabled, all elements of a breakdown source are counted against the limit. The count is taken before any scores are collected. Consider a case where the default limit of 10,000 elements is applied to a breakdown source with 1 million elements of which 5,000 have scores. Under nested collection, the job collects the scores for those 5,000 elements. With nested collection turned off, the job does not collect any scores for this breakdown source.
|
| com.snc.pa.dc.hsql.max_breakdown_elements_limit | Maximum number of breakdown elements retrieved by data collection for each breakdown source. If the number of elements on a breakdown source exceeds this limit, the data collector does not collect scores from that breakdown source. Important: This property applies only to jobs that use optimized data collection. Otherwise, com.snc.pa.dc.max_breakdown_elements_limit applies. For more information, see Optimizing data collection. This limit applies separately to each breakdown source included in a data collection job. The number of breakdowns associated with each breakdown source does not affect this limit. By default, no limit is set on the number of breakdown elements. If you experience performance issues on jobs with breakdown sources with large numbers of elements, consider setting a limit in consultation with Customer Service and Support. On upgrade to a later version than San Diego, optimized data collection is activated. This property then overrides com.snc.pa.dc.max_breakdown_elements_limit.
|
| com.snc.pa.dc.max_breakdown_elements_level2_limit | Maximum number of breakdown elements allowed in a matrix of two breakdowns. If this limit is exceeded, the breakdown elements in the matrix are not collected. Important: This property applies only to jobs that do not use optimized data collection. For optimized data collection, see the property com.snc.pa.dc.hsql.max_breakdown_elements_level2_limit.
Also see Optimizing data collection. For example, with the default limit of 1 million elements, a first-level breakdown with 10,000 elements, and a second-level breakdown with 500, the resulting matrix of 5 million elements is not collected. If the
first-level breakdown had only 1,000 elements, the resulting 500,000 elements would be collected. Note:
This limit is also affected by the com.snc.pa.dc.max_breakdown_elements_limit property. No
breakdown matrix is collected where one of the breakdown sources exceeds that limit.
|
| com.snc.pa.dc.hsql.max_breakdown_elements_level2_limit | Maximum number of breakdown elements allowed in a matrix of two breakdowns. If this limit is exceeded, the breakdown elements are not collected. Important: This property applies only to jobs that use optimized data collection. See Optimizing data collection. By default, no limit is set on the number of breakdown elements in a matrix. If you experience performance issues on jobs with breakdown sources with large numbers of elements, consider setting a limit in consultation with Customer Service and Support. Note:
This limit could be affected by the com.snc.pa.dc.hsql.max_breakdown_elements_limit property. If that limit is set, no breakdown matrix is collected where one of the breakdown sources exceeds that
limit.
|
| com.snc.pa.dc.max_error_count | The maximum number errors that may occur for a single data collection job run before data collection is stopped. Errors during data collection usually occur due to an invalid script, or when encountering the script timeout limit. If you encounter this limit, review any scripts that run during data collection to ensure that they are valid and perform as expected.
|
| com.snc.pa.dc.max_records | Maximum number of sys IDs that are stored in a single Snapshot [pa_snapshots] record. A Snapshot record is created for each collected score, and a field in this record contains all the sys IDs of the records that
contribute to the score. If this limit is exceeded, a Snapshot record is created with the maximum number of records. This limit applies only when Collect records is selected for an indicator. For example, say you are using the default limit of 5,000 and you run a job where 5,010 records contribute to the score. The system creates a Snapshot record with a comma-separated list of the first 5,000 sys IDs in the sys_id field. Generally, the default limit provides enough detail into collected records. Increasing this limit may impact performance during data collection or when performing operations on the Snapshot table.
|