Configure an SNC connection in Zero Copy Connector for ERP

  • Release version: Zurich
  • Updated March 12, 2026
  • 1 minute to read
  • Learn how to set up SNC, including preparing the environment, configuring the SAP system, and testing the configuration.

    Before you begin

    Role required: admin

    Confirm that you have the following:

    • An SNC-compatible security library, such as SAP Secure Login Library or a Kerberos-based library.
    • Administrative access to the SAP system and the server where it's hosted.

    Procedure

    1. Install the required security library on the MID Server by navigating to Connections & Credentials > Connection & Credential Aliases.
    2. Search for and open the Zero Copy Connector for ERP RFC alias with the ID sn_erp_integration.ERP_Canvas_RFC.
    3. In Related Links, select Create New Connection & Credential.
      Alias record with name, ID, and related link option highlighted.
    4. Complete the form.
    5. Restart the MID Server to apply the changes.
    6. Verify that the SNC configuration is working correctly.
      1. Go to All > Workflow Studio.
      2. On the home page, select Actions.
      3. Hover over the Name column and select the filter icon.
        Workflow Studio actions tab with name column filter icon highlighted.
      4. Filter for contains and type heartbeat.
      5. Select Apply.
      6. Select HeartBeat.
      7. Select Test.
      8. Specify a system and then select Run Test.
        Test action window with system field and run test button highlighted.
      9. When the test is complete, select the link Your test has finished running. View the Action execution details.
      10. Verify that the connection properties set are passed as input.
      11. Verify that isAlive is true, and if it's false, validate the parameters.